Ò»¡¢ÅäÖÃǰµÄ×¼±¸£º¿ªÆôVROC
×¢Ò⣺ÐèÒªÏȰÑbiosÏÂģʽͳһÐ޸ijÉUEFIģʽ¡£
µÇ¼µ½BIOS Setup½çÃæ£¬Ñ¡Ôñ¡°Advanced?CSM Configuration¡±½çÃæ£¬°´Enter¼ü£¬¶ÔBoot Mode Ñ¡Ïî½øÐÐÉèÖ㬿ɶÔϵͳµÄÆô¶¯Ä£Ê½£¨UEFI Mode/Legacy Mode£©½øÐÐÉèÖò¢ÏàÓ¦ÉèÖÃNetwork£¬Storage£¬Video Oprom Policy£¬Other PCI devicesµÄOption ROM µÄÖ´Ðз½Ê½,ÈçÏÂͼ5¸öÑ¡ÏîͳһÐ޸ijÉUEFI.

Ŀǰintel VROC½öÖ§³Öbios½çÃæÏÂÅäÖÃraid
Ê×ÏÈ£¬ÔÚÅäÖÃ֮ǰÐèÒªÏÈÐÞ¸ÄVMD configuration
Processor > IIO Configuration> Intel(R) VMD Technology
ÒÔNF5280M5ΪÀý£¬nvme½Ó¿ÚΪCPU1Ö§³Ö£¬ËùÒÔÐèÒªÐÞ¸Ä
Intel(R) VMD for volume Management Device on socket 1

ÆäÖС±PStack0¡å ºÍ ¡°PStack1¡å¶¼ÐèÒªÉèÖÃΪdisable, ¡°PStack2 ¡°ÐèÒªÉèÖÃΪenable ÆäËû²ÎÊýĬÈÏ

ÅäÖÃÍê³Éºóf10±£´æÖØÆô
¶þ¡¢RAIDÅäÖÃÓë¹ÜÀí
1¡¢²é¿´ÕóÁÐ
AdvacnedÏÂIntel(R) Virtual RAID on CPU

Ñ¡ÔñÒª²é¿´µÄÕóÁÐ

»Ø³µºó¿ÉÒÔ¿´µ½ÕóÁÐÏà¹ØÐÅÏ¢ºÍ³ÉÔ±ÅÌ

2¡¢É¾³ýÕóÁÐ
AdvacnedÏÂIntel(R) Virtual RAID on CPU
ÔÚIntel VROC Managed Vloumes Ï¿ÉÒÔ¿´µ½µ±Ç°´´½¨µÄraidÁбí
Ñ¡ÖÐÐèҪɾ³ýµÄraid»Ø³µ½øÈë

Ñ¡ÖÐdelete»Ø³µ

Ñ¡Ôñyes ɾ³ýraid£¨×¢Òâɾ³ýraidºóraidϵÄÊý¾Ý¶¼»á±»Çå³ý£¬½÷É÷²Ù×÷£©

3¡¢ÅäÖÃraid0
AdvacnedÏÂIntel(R) Virtual RAID on CPU
Ñ¡ÔñALL Intel VMD Controllers

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢
Ñ¡Ôñ Create RAID Volume

Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©
RAID Level£ºraid¼¶±ð
Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©
Select Disks: Ó²ÅÌÁбí
NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID0

Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ

Strip size Ìõ´øÖµÒ»°ãĬÈϼ´¿É
Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid

Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦

4¡¢ÅäÖÃraid1
×¢Ò⣺ĿǰVROCĬÈÏÖ§³Öraid0£¬ÈçÐèÅäÖà raid1¡¢10¡¢5ÐèÒªÖ÷°å¼Ókey
AdvacnedÏÂIntel(R) Virtual RAID on CPU
Ñ¡ÔñALL Intel VMD Controllers

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢
Ñ¡Ôñ Create RAID Volume

Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©
RAID Level£ºraid¼¶±ð
Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©
Select Disks: Ó²ÅÌÁбí
NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID1
Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ

Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid
Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦

5¡¢ÅäÖÃraid5
×¢Ò⣺ĿǰVROCĬÈÏÖ§³Öraid0£¬ÈçÐèÅäÖà raid1¡¢10¡¢5ÐèÒªÖ÷°å¼Ókey
AdvacnedÏÂIntel(R) Virtual RAID on CPU
Ñ¡ÔñALL Intel VMD Controllers

´Ëʱ¿ÉÒÔ¿´µ½Non-RAID physicalÏÂÓÐδÅäÖÃraidµÄÎïÀí´ÅÅÌÐÅÏ¢
Ñ¡Ôñ Create RAID Volume

Name£ºÃû×Ö£¨×Ô¶¨ÒåÒ²¿ÉÒÔʹÓÃĬÈÏ£©
RAID Level£ºraid¼¶±ð
Enable RAID spanned over VMD Controllers: ¿çÔ½VMD¿ØÖÆPGµç¾º¹ÙÍø´´½¨ÕóÁУ¨Ä¬Èϲ»¹´Ñ¡£©
Select Disks: Ó²ÅÌÁбí
NameĬÈϼ´¿É£¬raid levelÑ¡ÔñRAID5
Select disks Öпոñ¹´Ñ¡ÐèÒªÌí¼Óµ½raid×éÖеÄÓ²ÅÌ

Strip size Ìõ´øÖµÄ¬Èϼ´¿É
Capacity (GB) ÈÝÁ¿Ä¬ÈÏ·Ç×î´óÈÝÁ¿£¬¿É²Î¿¼maximum ÉèÖÃ×î´óÈÝÁ¿Ò²¿É×Ô¶¨ÒåÈÝÁ¿£¬Èç·Ç×î´óÈÝÁ¿£¬Ê£Óà¿Õ¼ä¿ÉÔٴδ´½¨raid

Ñ¡ÔñCreate Volume ¼´¿É´´½¨³É¹¦

6¡¢ÅäÖÃÈȱ¸ÅÌ
AdvacnedÏÂIntel(R) Virtual RAID on CPU
Ñ¡ÔñALL Intel VMD Controllers

ÔÚNon-RAID physical¿ÉÒÔ¿´µ½Î´ÅäÖôÅÅÌ£¬Ñ¡ÖÐÕâ¿éÅ̻سµ

Ñ¡Ôñmark as Spare

Ñ¡Ôñyes»Ø³µ

´Ëʱ²é¿´¸ÃÅÌ״̬£¬ÒѾÊÇSpare Èȱ¸ÅÌ

Èý¡¢³£¼ûÎÊÌâ
1£®ÎÞ·¨ÅäÖÃraid 0¡¢raid1¡¢5¡¢10
ÈôÎÞÅäÖÃraidÑ¡Ï»òÕßÖ»ÄÜÅäÖÃraid0,¶ø²»ÄÜÑ¡ÔñÀ©Õ¹raid,ÈçÐèÖ÷°åÐè¼Ókey
ÈçÏ¡±RAID_KEY¡±Î»ÖÿÉÒÔ°²×°NVMEµÄRAID KEY£¬Èç¹û²»°²×°VROCÖ»ÄÜ×öRAID0£¬°²×°ÁË¿ÉÒÔ×öÆäËûÀ©Õ¹RAID¡£

2£®µ¥Å̵ôÏß
µ±ÅäÖÃraid1¡¢5¡¢10ʱµ¥Å̵ôÏßÕóÁлáÌáʾ½µ¼¶degraded

¸ü»»ÐµÄÓ²Å̺ó»á×Ô¶¯rebuilding

Èç¹ûûÓÐ×Ô¶¯rebuildingÒ²¿ÉÒÔÔÚÅäÖýçÃæÏÂÊÖ¶¯rebuildÉÏÏßÓ²ÅÌ
Ñ¡ÔñÕóÁлسµ

Ñ¡ÔñRebuild»Ø³µ

Ñ¡ÖÐÐèÒªÉÏÏߵĴÅÅ̻سµ

»Ø³µºóÕóÁÐrebuilding

ÖØ½¨Íê³ÉºóÕóÁÐNormal״̬

3£®¶àÅ̵ôÏß
¶àÅ̵ôÏߣ¬ÕóÁÐfailed״̬£¬´ËʱÕóÁÐÒѲ»¿ÉÓã¬ÈçÊý¾ÝÖØÒª½¨ÒéѰÇóÊý¾Ý»Ö¸´»ú¹¹Ö§³Ö